= WGBS sequencing library preparation using KAPA protocol (Eppendorf) and epMotion = * Continued from: http://genome-tech.ucsd.edu/LabNotes/index.php/Noi/NOTES/2012-7-6 * Note that I used the same total volume of reaction similar to the protocol from Eppendorf. This might be slightly different from the original protocol from KAPA kit, but the total amount of enzyme is the same. I also adjust the volume of adapters in ligation step, but total volume and ratio of adapter to A-tailed DNA are the same. '''Image of sheared DNA (loaded 0.5ul)'''<br> <br> [[File:ZhangLab_2 2012-07-26 12hr 55min_PAGE-Quan-shearedDNA.png| 350px]] == Preparation of enzyme mix for End repair, A-tailing, Ligation, and Methylation adapters == * First of all, need to check if I have enough reagents for 8 rxn == Sample list == '''Labeled''' '''Sample IDs''' 1 GM12891 2 GM12892 3 GM10861 4 GM11994 5 GM11995 6 GM18506 7 GM18507 8 GM18505 '''End repair''' Total reaction in 70ul DNA 50ul End repair reaction mix 20ul KAPA End repair mix 1x rxn 8x rxn mix 10X End repai buffer 7.00 56.00 KAPA End repair enzyme 5.00 40.00 H2O 8.00 64.00 ================================================== Total 20.00 160.00 Aliquot to column #1: 20ul 20C for 30min '''A-tailing''' Total reaction in 30ul A-tailing reaction mix 1x rxn 8x rxn mix KAPA 10X A-tailing buffer 3.00 24.00 KAPA A-tailing enzyme 3.00 24.00 H2O 24.00 192.00 ================================================== Total 30.00 240.00 Aliquot to column #2: 30ul 30C for 30min '''Adapter ligation''' Total reaction in 50ul Ligation reaction mix 40ul Methylation adapter 10ul Ligation reaction mix 1x rxn 8x rxn mix KAPA 5X Ligation buffer 10.00 80.00 KAPA DNA ligase 5.00 40.00 H2O 25.00 200.00 ================================================== Total 40.00 320.00 Aliquot to column #3: 40ul '''Methylation adapter preparation''' ''Alan's note:'' 1. Use the methylated adapter with paired-end pcr primer pairs(PCR primer PE1.0 and PCR primer PE 2.0) provided in illumina's paired end genomic DNA sample prep kit 2. Use 10ul of methylated adapter to 5ug gDNA insert, if starting DNA amount is less than 5ug, titrate the volume of adapter reagent accordingly to maintain 10:1 ratio of DNA Since I used 1ug of DNA, used 2ul of adapters, but dilute to final volume 10ul (This volume is larger than KAPA protocol, but the total amount is the same) Methylation adapter 2ulx 8rxn 16.00 H2O 8ulx8rxn 64.00 ================================================== Total 80.00 20C for 15min '''Reagent preparation''' '''Reagents''' '''1rxn''' '''Min volume in 30mL reservior''' AMPure beads 120ul ~1.1mL 20% PEG/2.5M NaCl 90+50 = 140ul ~1.4mL 80% EtOH 140x6 = 840ul ~10.0mL H2O for elution 23ul ~1.0mL ==epMotion run == '''Report file of epMotion run:''' epMotion Started:5:00pm, finished: 7:30pm (~3hr for 8 samples) * Very important, when I added AMPure bead to end-repaired DNA and mixed for ten times, I have changed liquid type to water. This should be changed back to glycerol as before since the last step, the liquid was flushed out really quick, and it might cause contamination if bubbles are formed. * Note: ** After adapter ligation I eluted DNA with 23ul H2O, and transfered eluted DNA to 96-well plate (on the same plate, column #3) ** I checked adapter ligated DNA in 6% TBE gel (loaded 0.5 ul each, also load sheared DNA of sample #1 and #2 as control) [[File:ZhangLab_2 2012-07-27 20hr 33min_KAPA-adapter.jpg| 450px]] '''Labeled''' '''Sample IDs''' #1B = #1 before end repair #2B = #2 before end repair #1 GM12891 #2 GM12892 #3 GM10861 #4 GM11994 #5 GM11995 #6 GM18506 #7 GM18507 #8 GM18505 '''2012.07.30'''<br> # Took 1ul of Adapter ligated DNA and added to 8ul EB buffer -> for some validation, like qPCR or PAGE quantification to compare to the bisulfite conversion products '''qPCR to check if the end repair, A-tailing, and adapter ligation works''' {| {{table}} border = 1 | align="center" style="background:#f0f0f0;"|'''Components''' | align="center" style="background:#f0f0f0;"|'''1rxn''' | align="center" style="background:#f0f0f0;"|'''10 rxn mix''' |- | DNA template (1:9 diluted)||2.00||0.00 |- | 10uM PCR_F||1.00||10.00 |- | 10uM PCR_R.Ind1||1.00||10.00 |- | 2x iQ MM||25.00||250.00 |- | H2O||21.00||210.00 |- | Total||50.00||500.00 |} Program 95C 2min -> (95C 15sec -> 64C 20sec -> 72C 30sec) x 12 cycles 72C 3min 15C Hold # Run the gel check (the same labeled as above picture, but #1B, #1, #2B, #2, #3,....,#8) ## 2ul of 10x diluted adapter ligated DNA (the same amount that added to 50ul qPCR) ## 3ul of PCR product (out of 50ul) [[File:ZhangLab_2 2012-07-30 16hr 17min_adapterligated_qPCR.jpg| 400px]] # From the image above, I can see the amplification of all samples. This suggests that the reaction in the previous steps performed by epMotion worked very well. Even this result is not the final after bisulfite conversion, but it showed that the library prep before bisulfite conversion was success. == PROBLEM == * When I performed bisulfite conversion of these 8 adapter ligated DNA, the reaction leaked out from the plate at the end, and they leaked to another well beside. I need to discard all of these reactions and start over the library prep again. I still have 1ug of sheared DNA left. == CAUSE OF PROBLEM == * I never used this eppendorf plate for bisulfite conversion before. It should be the sealing problem because the well beside without DNA were sealed with plastic seal whereas the well with reaction sealed with a smalled strip of aluminum seal. The partial overlapping between the aluminum seal and plastic seal (on bottom) cause the reaction leaking. In the future, I should pay attention on sealing the plate seriously, since this problem never happen when I used the plate came with the kit and I did the bisulfite conversion on the whole plate and seal very well. * After I tested the plated by incubating few well of reagent at the same thermalcycler profile for Lightning MagPrep, I found that it's possible that I forgot to set the machine to heat lid. This because i observed the water drop on the top of the well even it didn't leak out like last time, but I didn't observed this when I heated the lid. * Continued on: http://genome-tech.ucsd.edu/LabNotes/index.php/Noi/NOTES/2012-8-1
Summary:
Please note that all contributions to ZhangLabWiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
ZhangLabWiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Create account
Log in
Namespaces
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Main Page
Current events
Recent changes
Random page
Investigators
Matt Cai
Song Chen
Eric Chu
Dinh Diep
Elizabeth Duong
Shicheng Guo
Alan Fung
Daniel Jacobsen
Blue Lake
Huy Lam
Alice Li
Andrew Richards
Brandon Sos
Chris Wei
Yan Wu
Kun Zhang
Tools
What links here
Related changes
Special pages
Page information