*'''Components:''' 1. microfluidic system 2. microincubator controller 3. microincubator manifold 4. 5% pre-mixed CO2 tank *'''System operation:''' 1. Attach the luer fittings from the "microincubator manifold" to the front panel of the "microfluidic system" and the "microincubator controller" in correct order (color matching). 2. Turn on "microfluidic system". Power indicater (red) and system ready light (blue) should be on. 3. Turn on "microincubator controller" if temperature and CO2 control is needed. Temperature display will show current temperature. Gas flow light (green) will be on once introduce the gas flow. 4. Turn the pressure adjusting knob of the CO2 tank. Make sure the gas flow is 45-55 psi. Check the remaining gas amount in tank. (Approximately usage is ~100 psi/24 hrs experiment.) 5. Open the CellASIC ONIX FG software on desktop.Select the plate type you are using. (Usually, mammalian M04S. For open top plate, select M04L.) 6. Make sure the status indicator on the bottom of the window says the system is ready. 7. Seal the manifold to the plate. Wipe the manifold clean with 70% EtOH (use Kimwipes). Align the manifold to the plate, and turn the vacuum on (Keep pushing down during sealing!). When the plate is properly sealed, the seal light (green) on the "microfluidic system" will be on. Sometimes it could be really difficult to seal a plate, if the plate is new. The system ready light (blue) might turn off during sealing. If this happens, turn the vacuum off and wait for the ready light to turn on again. Then, turn the vacuum back on. Repeat the process until plate is sealed. Don't let the vacuum be on while the ready light is off. Otherwise, the system would be over-heated and automatically shut down. 8. Place the sealed plate on microscope. 9. Go back to the software. Create protocols. Save it and run.
Summary:
Please note that all contributions to ZhangLabWiki may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
ZhangLabWiki:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Personal tools
Not logged in
Talk
Contributions
Create account
Log in
Namespaces
Page
Discussion
English
Views
Read
Edit
View history
More
Search
Navigation
Main Page
Current events
Recent changes
Random page
Investigators
Matt Cai
Song Chen
Eric Chu
Dinh Diep
Elizabeth Duong
Shicheng Guo
Alan Fung
Daniel Jacobsen
Blue Lake
Huy Lam
Alice Li
Andrew Richards
Brandon Sos
Chris Wei
Yan Wu
Kun Zhang
Tools
What links here
Related changes
Special pages
Page information