Kun:LabNotes/ExonomeSeq/2008-1-22: Difference between revisions

From ZhangLabWiki
Jump to navigation Jump to search
(New page: ==Exp. 1 2nd-round PCR on E55kv1 capturing amplicons== Templates: #1st-round amplicon(01/18/08) #PAGE purified 500bp+ 1st-round amplicon(01/18/08) #1 ...)
 
Line 13: Line 13:


     94C 2min -> (94C 30sec -> 72C 1min) x 10 -> 72C 3min -> 15C hold
     94C 2min -> (94C 30sec -> 72C 1min) x 10 -> 72C 3min -> 15C hold
  [[Image:2008-01-22-E55kv1-PCR-2nd.png|400px]]

Revision as of 19:12, 23 January 2008

Exp. 1 2nd-round PCR on E55kv1 capturing amplicons

Templates:

  1. 1st-round amplicon(01/18/08)
  2. PAGE purified 500bp+ 1st-round amplicon(01/18/08)
                        #1         #2
   Template            10ul       10ul
   2X Taq Master mix  100ul      100ul
   100uM AmpFV6.2Sol  0.8ul      0.8ul
   100uM AmpRV6.2Sol  0.8ul      0.8ul
   50x SYBG I         0.8ul      0.8ul
   H2O                 89ul       89ul
   94C 2min -> (94C 30sec -> 72C 1min) x 10 -> 72C 3min -> 15C hold
  File:2008-01-22-E55kv1-PCR-2nd.png