*A test of 5 different concentrations will be perform and image analysis using PISA will be performed to count the number of target being captured
*A test of 5 different concentrations will be perform and image analysis using PISA will be performed to count the number of target being captured


==Concentrations==
==MALAT1 Padlock Probes Concentrations to test ==
{| class="wikitable" <hiddentext>generated with [[:de:Wikipedia:Helferlein/VBA-Macro for EXCEL tableconversion]] V1.8<\hiddentext>
{| class="wikitable" <hiddentext>generated with [[:de:Wikipedia:Helferlein/VBA-Macro for EXCEL tableconversion]] V1.8<\hiddentext>
|- style="font-size:12pt"  valign="bottom"
|- style="font-size:12pt"  valign="bottom"
Line 21: Line 21:


|}
|}
==Protocol==
==Protocol==
*In this experiment we will be using the Mattek dish containing primary rolonies made on Oct 23rd dish #2
*In this experiment we will be using the Mattek dish containing primary rolonies made on Oct 23rd dish #2

Revision as of 21:42, 14 November 2013

Optimum Probe# Test

  • In this experiment we are trying to find the concentration of probes that works best for capturing rolony targets. From previous experiments we know that a concentration of 0.6uM with a volume of 100ul works.
  • A test of 5 different concentrations will be perform and image analysis using PISA will be performed to count the number of target being captured

MALAT1 Padlock Probes Concentrations to test

5uM
100nM
10nM
1nM
0.1nM

Protocol

  • In this experiment we will be using the Mattek dish containing primary rolonies made on Oct 23rd dish #2

Reagents

80% Formamide in 2X SSC
MALAT1 padlock probes
MALAT1 padlock probes detection

Apparatus

  • warm up incubator to 50C for incubation
  • warm up tube heater to 80C for pre-heating padlock probes

Stripping

Annealing

Imaging