Dinh:Protocols/Capturing Nov13: Difference between revisions

From ZhangLabWiki
Jump to navigation Jump to search
>Dinh
No edit summary
>Dinh
No edit summary
Line 1: Line 1:
=A. Bisulfite conversion of DNA using Zymo EZ DNA Methylation-Gold Kit
=A. Bisulfite conversion of DNA using Zymo EZ DNA Methylation-Gold Kit=


Reaction Mix (1x, 150ul):  
Reaction Mix (1x, 150ul):  
Line 30: Line 30:
Measure the DNA with Nanodrop.
Measure the DNA with Nanodrop.


=B. Capturing Protocol CpG30K
=B. Capturing Protocol CpG30K=


Positive control: Jurkat converted DNA  
Positive control: Jurkat converted DNA  
Negative control: 1ul RNAse free ddH20
Negative control: 1ul RNAse free ddH20

Revision as of 00:52, 14 November 2009

A. Bisulfite conversion of DNA using Zymo EZ DNA Methylation-Gold Kit

Reaction Mix (1x, 150ul):

 Jurkat DNA (203.9ng/ul) - 10ul 
 RNase free ddH20 - 10 ul
 (DNA = 2.039ug)
 Conversion Reagent (prepared 11/6) - 130 ul

Reaction Program:

 98C -> 10 min
 64C -> 2.5 hours
 4C -> overnight

Place a Zymo-Spin IC Column into a provided Collection tube. Add 600 ul of M-Binding Buffer to spin column Load the reaction mix into the spin column. Close cap and mix by inverting 10 times. Centrifuge at 15K rpm for 30 s. Discard flow through. Add 100ul of M-Wash Buffer. Centrifuge at 15K rpm for 30 s. Discard flow through. Add 200ul M-Desulphonation Buffer and wait for 20 min. Centrifuge at 15K rpm for 30 s. Discard flow through. Add 200ul M-Wash Buffer. Centrifuge at 15K rpm for 30 s. Discard flow through. Add another 200ul M-Wash Buffer. Centrifuge at 15K rpm for 30 s. Discard flow through.

Place the column into 1.5ml microcentrifuge tube. Add 12ul M-Elution Buffer into center of column matrix. Wait 1 min. Centrifuge at 15K rpm for 30 s. Discard flow through. Measure the DNA with Nanodrop.

B. Capturing Protocol CpG30K

Positive control: Jurkat converted DNA Negative control: 1ul RNAse free ddH20