Line 11: Line 11:
**0.8 to 1 uL keeps DNA above 300 bp ish usually
**0.8 to 1 uL keeps DNA above 300 bp ish usually
**adjust ratios accordingly
**adjust ratios accordingly
*2. Place on magnetic stand.
*2. Place on magnetic stand, edges of tubes lying down if want.
*3. After 5 minutes, remove supernatant, wash with 180ul fresh made 80% EtOH twice.
*3. After 5 minutes, remove supernatant, wash with 180ul fresh made 80% EtOH twice.
*4. Remove from magnetic stand. Air-dry for 15min, re-suspend with 25ul Qiagen EB (or nuclease free H2O), mix 10 times, let sit at RT for 2min, then place in magnetic stand.
*4. Remove from magnetic stand. Air-dry for 15min, pipet out EtOH after 15 minutes with gel tip, re-suspend with 25ul Qiagen EB (or nuclease free H2O), mix 10 times so all beads are resuspended, let sit at RT for 2min, then place in magnetic stand.
*5. After 2 minutes, transfer 20 ul DNA from beads (leave a little so don't pick up beads), 1ul left in tube for Qubit measurement
*5. After 2 minutes, transfer 20 ul DNA from beads (leave a little so don't pick up beads), 1ul left in tube for Qubit measurement

Revision as of 22:21, 17 April 2012

AMPure beads purification protocol

  • Purification with AMPure beads


  • 1. Add 50ul beads to 50ul reaction (or 1 volume to 1 volume), mix 10 times, R.T for 8min
    • can do 1.8 uL beads to 1 uL PCR product, will retain more DNA sample
    • 1.8 to 1 uL keeps DNA above 100 bp ish usually
    • 1.0 to 1 uL keeps DNA above 200 bp ish usually
    • 0.8 to 1 uL keeps DNA above 300 bp ish usually
    • adjust ratios accordingly
  • 2. Place on magnetic stand, edges of tubes lying down if want.
  • 3. After 5 minutes, remove supernatant, wash with 180ul fresh made 80% EtOH twice.
  • 4. Remove from magnetic stand. Air-dry for 15min, pipet out EtOH after 15 minutes with gel tip, re-suspend with 25ul Qiagen EB (or nuclease free H2O), mix 10 times so all beads are resuspended, let sit at RT for 2min, then place in magnetic stand.
  • 5. After 2 minutes, transfer 20 ul DNA from beads (leave a little so don't pick up beads), 1ul left in tube for Qubit measurement