Hosuk:LabNotes/2013-4-23: Difference between revisions
Jump to navigation
Jump to search
>Hosuki78 (Created page with "====RCA test with the product of CircLigase II reaction==== =====Goal===== *Verify that there are circularized DNA in the CircLigase II reaction sample =====Experiment Proce...") |
>Hosuki78 No edit summary |
||
Line 6: | Line 6: | ||
=====Experiment Procedure===== | =====Experiment Procedure===== | ||
*Run RCA | *Run RCA | ||
**S1 : CircLigase II reaction sample (18hr. @ 30°C) | |||
**S2 : -CircLigase II sample (No CircLigase II Enzyme while CircLigase II reaction) (18hr. @ 30°C) | |||
**Protocol | **Protocol | ||
[[File:RCAReationProtocolinTube.jpg| | **[[File:RCAReationProtocolinTube.jpg|350px]] | ||
*Mixing Cy3-Adapter | |||
**4.5uL of each RCA sample + 0.5uL of 100uM Cy3-Adapter | |||
**S1 : +CircLigase II + Cy3-Adapter | |||
**S2 : -CircLigase II + Cy3-Adapter | |||
**S3 : H2O + Cy3-Adapter |
Revision as of 00:20, 24 April 2013
RCA test with the product of CircLigase II reaction
Goal
- Verify that there are circularized DNA in the CircLigase II reaction sample
Experiment Procedure
- Run RCA
- S1 : CircLigase II reaction sample (18hr. @ 30°C)
- S2 : -CircLigase II sample (No CircLigase II Enzyme while CircLigase II reaction) (18hr. @ 30°C)
- Protocol
- File:RCAReationProtocolinTube.jpg
- Mixing Cy3-Adapter
- 4.5uL of each RCA sample + 0.5uL of 100uM Cy3-Adapter
- S1 : +CircLigase II + Cy3-Adapter
- S2 : -CircLigase II + Cy3-Adapter
- S3 : H2O + Cy3-Adapter