AlanFung:Protocol/Construction of Solexa sequencing Library

From ZhangLabWiki
Revision as of 18:11, 29 October 2009 by >Alan6017518
Jump to navigation Jump to search

Construction of Solexa sequencing library from padlock captured PCR products using NEBNext DNA Sample Prep Master Mix Set 1 Kit (E6040S/L)

  • The NEBNext DNA SPMMS 1 (I) is compatible with protocols requiring a 3´ A overhang on the library molecules to facilitate ligation to adapters containing a 5´ T overhang, such as Illumina’s Genomic DNA Sample Prep protocol for the Genome Analyzer II.

Overview

  • Fragmentation and end-polishing
  • Size Selection
  • Ligation
  • PCR of sequencing Library
  • QPCR quantification


Fragmentation and end-polishing (Make blunt ends with 5'P)

  • The PCR amplicons (200ng-1ug) are fragmented with Covaris sonicator to ~100bp
  • End-Repair Reactions
Fragmented DNA 85ul
10X End Repair Bufer 10ul
End Repair Enzyme Mix 5ul
  • Incubate tubes at RT for 30minutes.
  • Perform a Qiaquick purification and elute with 39ul EB buffer.
  • NOTE: For blunt-end ligation, the A-Tailing reaction should be skipped. Doing TA ligation is preferable since it eliminates the chance of getting chimeric reads.
  • A-Tailing Reactions
Blunet-end DNA 37ul
10X dA-Tailing Reaction Buffer 5ul
Klenow Fragment (3'-5' exo-) 3ul
H2O 5ul