Capture Test of CES36k18bp
Jump to navigation
Jump to search
Capture Protocol
Probe and Sample
Probes: CES36k18bp, 5.6ng/ul Sample is Jurkat DNA standard, 100ng/ul (2.00ul) The Probe:Target ratio is 100:1
SLN Mix: Stoffel 2U/ul + AMPLigase 4U/ul + dNTP 0.25mM
Calculations
Probe:
CES36k18bp: 5.6ng/ul; 36,000 probes; 170nM Volume of CES36k18bp needed = (200ng/3pg * 100 * 36000)/(6.0 * 10^23 * 170 nM) = 2.35ul
Reaction Setup
Jurkat DNA: 2.00ul 10X AMPLigase Buffer: 1.50ul CES36k18bp: 2.35ul H2O: 14.15ul 94C, 5min -> -0.1C/sec to 60C -> 60C, 24h -> add 2ul SLN mix -> 60C, 24h -> 95C, 2min -> 37C, 1min -> add 2ul Exo I&III -> 37C, 2h -> 94C, 5min -> 4C hold
PCR
Template: 8ul 2X Phusion mix: 50ul 100uM AmpF6.3NH2: 0.2ul 100uM AmpR6.3NH2: 0.2ul 50X SYBG: 0.4ul H2O: 30ul
98C, 30sec -> (98C, 10sec -> 58C, 20sec -> 72C, 20sec -> read) x 20 -> 72C, 3min -> 4C hold