Reagent Preparation

 dNTP concentration 10mM(NEB)
                                                                    ddH2O     Ligase Buffer   Ligase     Amplitaq    dNTP           
 2U/ul AmpliTaq Stoffel fragment; 0.5U/ul AmpLigase; 1mM dNTP:      0.5ul         0.1ul       0.1ul       0.2ul    (10mM)0.1ul 
                                                           x30       15ul          3ul        3ul        6ul      3ul

Overview

  • Bisulfite Conversion of DNA
  • Capturing Reaction

Calculation

Probe:target ratio 200:1 (according to Alice, 100:1 works too)

NIH_3T3_gDNA Template(100ng/uL)
Use 200ng total, so = 2uL
  • One genome mass = 3pg
  • First calculate the # of genome your target represents
  • For 200ng, it represents 200ng/3pg=66666.67 genomes
  • You want to have 200x the probes as the target 200ng/3pg*200
  • You want every single probe to target ratio to be 200:1 200ng/3pg*200*55,000
Ms_Meth 22ng/uL 55,000Probes 100nt
Since 1 base = 330Da (for single stranded DNA, 660Da for ds), 
the concentration of probe is 22 ng/ul /(100x330) = 0.000666667 = 666.67nM
# of molecules per mole = 6X10^23
# of probes needed/ concentration of probes = Volume of probes needed
the volume the probe needed is 200ng/3pg x 200 x 55,000 / [(6x10^23)x (666.67*10^-9M)]*10^6 =1.83uL

Procedures

Bilsulfite Conversion with EZ DNA Methylation-Gold Kit

  • Add 900ul ddH2O, 300ul M-Dilution Buffer and 50ul M-Dissolving Buffer to a tube of CT Conversion Reagent vortex for 10M
  • Add 24mL of 100% ethanol to the 6mL M-Wash Buffer concentrate
  • Add 130ul of CT conversion reagent to samples. If your DNA sample is less than 20uL make up the difference with H2O
  • Mix the sample and perform
  • 98C 10min -> 64C 150min -> 4c overnight.
  • Add 600ul M-Binding buffer to spin columns.
  • Add the converted samples to the columns, close the gap and mix by inverting several times.
  • Spin at 15,000rpm for 30sec, discard flow through
  • Add 100ul M-Wash Buffer, spin for 30 sec, discard flow-through.
  • Add 200ul M-Desulphonation Buffer, wait for 20min, spin at 15,000 rpm for 30sec.
  • Add 200ul M-Wash Buffer, spin for 30 sec.
  • Place the columns into 1.5ml tubes, add 10ul M-Elution Buffer. Wait for 1min, spin at 15,000rpm for 30sec.
  • Measure the DNA with Nanodrop:

RNA

Capturing System Setup

  CT Converted Ms-gDNA            
  10X AmpLigase buffer             
  Ms_Meth Probe (242.4nM)          
  H2O                              
  Total                            
95c 10min -> 60C 24h ->add 2ul SLN mix(2U/ul AmpliTaq Stoffel fragment; 0.5U/ul AmpLigase; 1mM dNTP) -> 60C 4h -> 
4 cycels (95C 1min -> 55C for 4h),add 2ul more SLN mix after 1st cycle -> 95C 5min ->
add 2ul Exonuclease I/III mixadd 2ul Exonuclease I/III mix as soon as the temperature is lowered to 37C -> 37C 1h -> 94C 5min -> 4C hold